9132 and 9133 Portable Infrared Calibrators

ขอใบเสนอราคา

 

 

Description

Fluke 9132  : blackbody calibration up to 500 °C
For IR calibrations above normal ambient, the Fluke 9132 blackbody calibration source provides a stable measurement surface up to 500 °C (932 °F). Short heating and cooling times mean you won’t have to wait long to get your work done.

Fluke 9133  : blackbody calibration from -30 °C to 150 °C
If you’re calibrating IR thermometers at cold temperatures, you’ll love our new Fluke 9133 blackbody calibration source. With solid-state cooling technology, this new IR calibrator reaches –30°C (22°F) in normal ambient conditions. With a conveniently located dry gas fitting on the front bezel, ice build up on the target can be avoided. At the upper end of its range, the Fluke 9133 provides stable temperatures to 160°C (320°F).

With heating and cooling times of about 15 minutes from ambient to either extreme, the Fluke 9133 gets you to temperature quickly and performs when it gets there.

Highlights

Precision when you need it for infrared temperature calibration

Fluke 9132 and Fluke 9133 Portable Infrared Calibrators features:

  • Certify IR pyrometers from –30 °C to 500 °C (–22 °F to 932 °F)
  • Large 57 mm (2.25 in) blackbody target
  • RTD reference well for contact temperature measurement
  • Small, compact design in a blackbody calibrator 

Whether you’re using in-line or handheld infrared pyrometers, you need good calibration standards to verify their accuracy. Our portable IR calibrators provide stable blackbody targets for calibrating noncontact IR thermometers from –30 °C to 500 °C.

These blackbody calibrator units feature a temperature controlled measurement surface with a diameter of 2.25 in (57 mm). The target temperature can be controlled in set-point increments of 0.1° from –30 °C to 500 °C and a well is located directly behind the blackbody surface for contact calibration.

Specifications

Specifications

9133 9132
Temperature Range –30 °C to 150 °C at 23 °C ambient
(–22 °F to 302 °F at 73 °F ambient)
50 °C to 500 °C
(122°F to 932°F)
Accuracy ± 0.4 °C (± 0.72 °F)
 
 
 
± 0.5 °C at 100 °C
(± 0.9°F at 212°F)
± 0.8 °C at 500 °C
(± 1.4 °F at 932 °F)
Stability ± 0.1 °C (± 0.18 °F)
 
 
 
± 0.1°C at 100°C
(± 0.18°F at 212°F)
± 0.3°C at 500°C
(± 0.54°F at 932°F)
Target Size 57 mm (2.25 in)
Target Emissivity 0.95 (± 0.02 from 8 to 14 µm)
Resolution 0.1 °
Heating Time 15 minutes (25 °C to 150 °C) 30 minutes (50 °C to 500 °C)
Cooling Time 15 minutes (25 °C to –20 °C) 30 minutes (500 °C to 100 °C)
Computer Interface RS-232 interface
Power 115 V ac (± 10 %), 1.5 A, or
230 V ac (± 10 %), 1.0 A,
switchable, 50/60 Hz, 200 W
115 V ac (± 10 %), 3 A or
230 V ac (± 10 %), 1.5 A,
switchable, 50/60 Hz, 340 W
Size (HxWxD)
152 x 286 x 267 mm
(6 x 11.25 x 10.5 in)
102 x 152 x 178 mm
(4 x 6 x 7 in )
Weight 4.6 kg (10 lb) 1.8 kg (4 lb)
NIST-Traceable
Contact Calibration
Data at –30°C, 0°C, 25°C, 75°C, 100°C, 125°C, and 150°C Data at 50°C, 100°C, 200°C, 250°C, 300°C, 400°C, and 500°C

Models and Accessories

Model Name Description
9132 Portable IR Calibrator, 500 °C
9133 Portable IR Calibrator, –30 °C

Accessories common to all models  :

Accessory Description
9302 Rugged Carrying Case (holds 1560 and up to five modules)
Priority Gold Instrument CarePlan Fluke Calibration Priority Gold Instrument CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote.
Silver CarePlan Fluke Calibration Silver CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. 

Knowledge and Information

Product Manuals

Brochures

Application Notes

Papers / Articles

On-Demand Webinars

 

Video

Emissivity Makes a Temperature Difference Video