The Fluke 113 Digital Multimeter gives users the means to quickly and easily do basic meter set and reconnect testing. This meter is simple-to-use and has the features needed to repair most electrical problems. The Fluke 113 has significant improvements over other digital multimeters available on the market, including Fluke model 7-600. Using the Fluke VCHEK™ LoZ low impedance measurement function, users can simultaneously test for voltage or continuity. The Min/Max function lets you record signal fluctuations. The Fluke 113 can perform diode tests, and also provides both auto and manual ranging capabilities. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this meter is a must have for every toolbox.

Features

  • VCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity
  • True RMS for accurate AC measurements on non-linear loads
  • A large backlit display allows for easy visibility in low-lit areas
  • Record signal fluctuations using the Min/Max function
  • Diode test for testing general-purpose germanium, silicon, and power diodes
  • Integral holster with probe holders for easy storage
  • Auto and Manual ranging for added user functionality
  • Meets Measurement Category CAT III 600 V and Category IV 300 V standards for a higher level of safety
  • The optional TPAK magnetic hanger allows the user hands-free flexibility

Specifications

Specifications
VCHEK1 2 3Range6.000 V / 60.00 V / 600.0 V
Resolution0.001 V / 0.01 V/ 0.1 V
AccuracyDC, 45 to 500 Hz: 2.0% + 3
500 Hz to 1 kHz: 4.0% + 3
Diode test4Range2.000 V
Resolution0.001 V
Accuracy2.0% + 3
Continuity4AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer
Ω4Range600.0 Ω / 6.000 kΩ / 60.00 kΩ
Resolution0.1 Ω / 0.001 kΩ / 0.01 kΩ
Accuracy0.9% + 2 / 0.9% + 1 / 0.9% + 1
Capacitance4Range1000 nF / 10.00 μF / 100.0 μF / 9999 μF
Resolution1 nF / 0.01 μF / 0.1 μF / 1 μF
Accuracy1.9% + 2
100 μF – 1000 μF: 1.9% + 2
1000 μF: 5% + 20
1. All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together.
2. Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale.
3. Minimum measureable input in VCHEK autorange is 3 VDC. For measurements below 3 VDC, push Range button twice to get to 6 VDC manual range.
4. After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity.
Specifications
Maximum voltage between any terminal and earth ground600 V
Display3 3/4-digits, 6000 counts, updates 4/sec
Operating temperature-10°C to 50°C (14°F to 122°F)
Storage temperature-40°C to 60°C (-22°F to 140°F)
Temperature coefficient0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Operating altitude2,000 m
Storage altitude10,000 m
Relative humidity95% to 30°C
75% to 40°C
45% to 50°C
Battery type9 Volt Alkaline, ANSI 1604A / IEC 6F22
Battery lifeAlkaline: 300 hours typical, without backlight
Shock1 Meter drop per IEC 61010–1–2001
VibrationPer MIL-PRF-28800 for Class 2 instrument
Size (H x W x L)167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in)
Weight13.0 oz (404 g)
SafetyComplies with ANSI / ISA 82.02.01 (61010–1) 2004, CAN / CSA-C22.2 No 61010-1-04, UL 61010–1 (2004) and IEC / EN 61010–1 2nd Edition for measurement Category IV, 600 V, Pollution Degree 2, EMC EN61326–1
EMI regulationsComplies with FCC Part 15, Class B
Specifications
VCHEKInput impedance (nominal)~3 kΩ < 300 pF
VCHEKCommon mode rejection ratio
(1 kΩ unbalanced)
> 60 dB at DC, 50 or 60 Hz
ΩOpen circuit test voltage< 2.7 VDC
Full scale voltage< 0.7 VDC
Diode testOpen circuit test voltage2.7 VDC
Full scale voltage2.000 VDC
ΩShort circuit current< 350 μA
Diode testShort circuit current< 1.0 mA

Models

Models
Model NameDescription
Fluke 113Fluke 113 Digital Multimeter
Includes

  • Fluke TL75 test leads
  • Holster
  • Users manual
  • and 9 V battery (installed)

Accessories

Accessory Kits
Model NameDescription
Fluke TLK 220Fluke TLK-220 US SureGripTM Industrial Test Lead
Cases & Holsters
Model NameDescription
Fluke C35Fluke C35 Soft Carrying Case
Fluke C50Fluke C50 Meter Case
Fluke TPAKFluke TPAK ToolPakTM Magnetic Meter Hanger
Test Leads
Model NameDescription
Fluke TL223Fluke TL223 SureGripTM Electrical Test Lead Set
Test Leads, Probes & Clips
Model NameDescription
Fluke TL175Fluke TL175 TwistGuardTM Test Leads

 

Knowledge and Information

Manuals
Title
113 Calibration InformationDownload
113 Calibration Information SupplementDownload
113 Instruction SheetDownload
113 Instruction Sheet SupplementDownload
117, 116, 115, 114, 113 and 110 Plus Statement of Memory VolatilityDownload
Application Notes
Title
ABCs of Multimeter safety: Multimeter Safety and YouDownload
Revenue meter socket checks using the Fluke 113 Utility MultimeterDownload
Troubleshooting power harmonicsDownload
Brochures
Title
Add Wireless to Your Fluke Digital MultimeterDownload
Fluke 113 Family Brochure InsertDownload
Fluke Digital Multimeter Selection GuideDownload
Data Sheets
Title
Fluke 113 Data SheetDownload
Demos
Title
How to Diagnose PMW Peak Voltage Using a Multimeter and a ScopeDownload