Fluke 113 Digital Multimeter

The Fluke 113 Utility Multimeter is a must-have for every toolbox, with its easy to view, large, backlit display and simple, one-hand operation.

ขอใบเสนอราคา

 

 

Overview

The Fluke 113 Digital Multimeter gives users the means to quickly and easily do basic meter set and reconnect testing. This meter is simple-to-use and has the features needed to repair most electrical problems. The Fluke 113 has significant improvements over other digital multimeters available on the market, including Fluke model 7-600. Using the Fluke VCHEK™ LoZ low impedance measurement function, users can simultaneously test for voltage or continuity. The Min/Max function lets you record signal fluctuations. The Fluke 113 can perform diode tests, and also provides both auto and manual ranging capabilities. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this meter is a must have for every toolbox.

Features

  • VCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity
  • True RMS for accurate AC measurements on non-linear loads
  • A large backlit display allows for easy visibility in low-lit areas
  • Record signal fluctuations using the Min/Max function
  • Diode test for testing general-purpose germanium, silicon, and power diodes
  • Integral holster with probe holders for easy storage
  • Auto and Manual ranging for added user functionality
  • Meets Measurement Category CAT III 600 V and Category IV 300 V standards for a higher level of safety
  • The optional TPAK magnetic hanger allows the user hands-free flexibility

Specifications

Specifications
VCHEK1 2 3 Range 6.000 V / 60.00 V / 600.0 V
Resolution 0.001 V / 0.01 V/ 0.1 V
Accuracy DC, 45 to 500 Hz: 2.0% + 3
500 Hz to 1 kHz: 4.0% + 3
Diode test4 Range 2.000 V
Resolution 0.001 V
Accuracy 2.0% + 3
Continuity4 Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer
Ω4 Range 600.0 Ω / 6.000 kΩ / 60.00 kΩ
Resolution 0.1 Ω / 0.001 kΩ / 0.01 kΩ
Accuracy 0.9% + 2 / 0.9% + 1 / 0.9% + 1
Capacitance4 Range 1000 nF / 10.00 μF / 100.0 μF / 9999 μF
Resolution 1 nF / 0.01 μF / 0.1 μF / 1 μF
Accuracy 1.9% + 2
100 μF – 1000 μF: 1.9% + 2
1000 μF: 5% + 20
1. All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together.
2. Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale.
3. Minimum measureable input in VCHEK autorange is 3 VDC. For measurements below 3 VDC, push Range button twice to get to 6 VDC manual range.
4. After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity.
Specifications
Maximum voltage between any terminal and earth ground 600 V
Display 3 3/4-digits, 6000 counts, updates 4/sec
Operating temperature -10°C to 50°C (14°F to 122°F)
Storage temperature -40°C to 60°C (-22°F to 140°F)
Temperature coefficient 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Operating altitude 2,000 m
Storage altitude 10,000 m
Relative humidity 95% to 30°C
75% to 40°C
45% to 50°C
Battery type 9 Volt Alkaline, ANSI 1604A / IEC 6F22
Battery life Alkaline: 300 hours typical, without backlight
Shock 1 Meter drop per IEC 61010–1–2001
Vibration Per MIL-PRF-28800 for Class 2 instrument
Size (H x W x L) 167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in)
Weight 13.0 oz (404 g)
Safety Complies with ANSI / ISA 82.02.01 (61010–1) 2004, CAN / CSA-C22.2 No 61010-1-04, UL 61010–1 (2004) and IEC / EN 61010–1 2nd Edition for measurement Category IV, 600 V, Pollution Degree 2, EMC EN61326–1
EMI regulations Complies with FCC Part 15, Class B
Specifications
VCHEK Input impedance (nominal) ~3 kΩ < 300 pF
VCHEK Common mode rejection ratio
(1 kΩ unbalanced)
> 60 dB at DC, 50 or 60 Hz
Ω Open circuit test voltage < 2.7 VDC
Full scale voltage < 0.7 VDC
Diode test Open circuit test voltage 2.7 VDC
Full scale voltage 2.000 VDC
Ω Short circuit current < 350 μA
Diode test Short circuit current < 1.0 mA

Models

Models
Model Name Description
Fluke 113 Fluke 113 Digital Multimeter
Includes

  • Fluke TL75 test leads
  • Holster
  • Users manual
  • and 9 V battery (installed)

Accessories

Accessory Kits
Model Name Description
Fluke TLK 220 Fluke TLK-220 US SureGripTM Industrial Test Lead
Cases & Holsters
Model Name Description
Fluke C35 Fluke C35 Soft Carrying Case
Fluke C50 Fluke C50 Meter Case
Fluke TPAK Fluke TPAK ToolPakTM Magnetic Meter Hanger
Test Leads
Model Name Description
Fluke TL223 Fluke TL223 SureGripTM Electrical Test Lead Set
Test Leads, Probes & Clips
Model Name Description
Fluke TL175 Fluke TL175 TwistGuardTM Test Leads

 

Knowledge and Information

Manuals
Title
113 Calibration Information Download
113 Calibration Information Supplement Download
113 Instruction Sheet Download
113 Instruction Sheet Supplement Download
117, 116, 115, 114, 113 and 110 Plus Statement of Memory Volatility Download
Application Notes
Title
ABCs of Multimeter safety: Multimeter Safety and You Download
Revenue meter socket checks using the Fluke 113 Utility Multimeter Download
Troubleshooting power harmonics Download
Brochures
Title
Add Wireless to Your Fluke Digital Multimeter Download
Fluke 113 Family Brochure Insert Download
Fluke Digital Multimeter Selection Guide Download
Data Sheets
Title
Fluke 113 Data Sheet Download
Demos
Title
How to Diagnose PMW Peak Voltage Using a Multimeter and a Scope Download